Specifications
Voltage class Single-phase 200 V
Inverter model CIMR-VCBA*
1
0001 0002 0003 0006 0010 0012 00018*
6
Inverter output
Motor output kW at normal duty*
2
0.18 0.37 0.75 1.1 2.2 3.0 –
Motor output kW at heavy duty *
2
0.1 0.18 0.55 0.75 1.5 2.2 4.0
Rated output current at normal duty [A]*
3
1.2 1.9 3.3 6 9.6 12 –
Rated output current at heavy duty [A] 0.8*
4
1.6*
4
3.0*
4
5.0*
4
8.0*
5
11.0*
5
17.5*
5
Overload
125% for 60 sec normal duty, 150 % for 60 sec
at heavy duty from inverter rated output current
Rated output power at normal duty [kVA]* 0.5 0.7 1.3 2.3 3.7 4.6 -
Rated output power at heavy duty [kVA]* 0.3 0.6 1.1 1.9 3.0 4.2 6.7
Max. output voltage Three-phase 200 to 240 V (proportional to input voltage)
Max. output frequency 400 Hz
Inverter
input
Rated input voltage Single-phase 200 to 240 V, -15% to +10%
Rated input frequency 50/60 Hz, ±5%
* based on input voltage 220 V
Voltage class Three-phase 200 V
Inverter model CIMR-VC2A 0001 0002 0004 0006 0010 0012 0020 0030 0040 0056 0069
Inverter output
Motor output kW at normal duty*
2
0.18 0.37 0.75 1.1 2.2 3.0 5.5 7.5 11.0 15.0 18.5
Motor output kW at heavy duty*
2
0.1 0.2 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11.0 15.0
Rated output current at normal duty [A]*
3
1.2 1.9 3.5 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0
Rated output current at heavy duty [A] 0.8*
4
1.6*
4
3.0*
4
5.0*
4
8.0*
5
11.0*
5
17.5*
5
25.0*
5
33.0*
5
47.0*
5
60.0*
5
Overload 120% for 60 sec at normal duty, 150% for 60 sec at heavy duty from inverter rated output current
Rated output power at normal duty [kVA]* 0.5 0.7 1.3 2.3 3.7 4.6 7.5 11.4 15.2 21.3 26.3
Rated output power at heavy duty [kVA]* 0.3 0.6 1.1 1.9 3.0 4.2 6.7 9.5 12.6 17.9 22.9
Max. output voltage Three-phase 200 to 240 V (proportional to input voltage)
Max. output frequency 400 Hz
Inverter
input
Rated input voltage Three-phase 200 to 240 V, -15% to +10%
Rated input frequency 50/60 Hz, ±5%
* based on input voltage 220V
Voltage class Three-phase 400 V
Inverter model CIMR-VC4A 0001 0002 0004 0005 0007 0009 0011 0018 0023 0031 0038
Inverter output
Motor output kW at normal duty*
2
0.37 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15.0 18.5
Motor output kW at heavy duty*
2
0.18 0.37 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0
Rated output current at normal duty [A]*
3
1.2 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23.0 31.0 38.0
Rated output current at heavy duty [A]*
5
1.2 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 24.0 31.0
Overload 120% for 60 sec at normal duty, 150% for 60 sec at heavy duty from inverter rated output current
Rated output power at normal duty [kVA]* 0.9 1.6 3.1 4.1 5.3 6.7 8.5 13.3 17.5 23.6 29.0
Rated output power at heavy duty [kVA]* 0.9 1.4 2.6 3.7 4.2 5.5 7.0 11.3 13.7 18.3 23.6
Max. output voltage Three-phase 380 to 480 V (proportional to input voltage)
Max. output frequency 400 Hz
Inverter
input
Rated input voltage Three-phase 380 to 480 V, -15% to +10%
Rated input frequency 50/60 Hz, ±5%
* based on input voltage 400 V
*
1
Drives with a single-phase power supply input have three-phase output. Single-phase motors cannot be used.
*
2
The motor capacity (kW) refers to a YASKAWA 4-pole, 60 Hz, 200 V motor. The rated output current of the drive output amps should be equal to or greater than the motor rated current.
*
3
at 2 kHz carrier frequency without derating
*
4
at 10 kHz carrier frequency without derating
*
5
at 8 kHz carrier frequency without derating
*
6
only heavy duty available