Options
Name Purpose Model, Manufacturer
Input noise filter
Reduces noise from the line that enters into the drive input power system.
Should be installed as close as possible to the drive.
1-phase 200 V Filter:
CIMR-VCBA0001 FS23638-10-07
CIMR-VCBA0002 FS23638-10-07
CIMR-VCBA0003 FS23638-10-07
CIMR-VCBA0006 FS23638-20-07
CIMR-VCBA0010 FS23638-20-07
CIMR-VCBA0012 FS23638-30-07
CIMR-VCBA0018 FS23638-40-07
3-phase 200 V Filter:
CIMR-VC2A0001 FS23637-8-07
CIMR-VC2A0002 FS23637-8-07
CIMR-VC2A0004 FS23637-8-07
CIMR-VC2A0006 FS23637-8-07
CIMR-VC2A0010 FS23637-14-07
CIMR-VC2A0012 FS23637-14-07
CIMR-VC2A0020 FS23637-24-07
CIMR-VC2A0030 FS23637-52-07
CIMR-VC2A0040 FS23637-52-07
CIMR-VC2A0056 FS23637-68-07
CIMR-VC2A0069 FS23637-80-07
3-phase 400 V Filter:
CIMR-VC4A0001 FS23639-5-07
CIMR-VC4A0002 FS23639-5-07
CIMR-VC4A0004 FS23639-5-07
CIMR-VC4A0005 FS23639-10-07
CIMR-VC4A0007 FS23639-10-07
CIMR-VC4A0009 FS23639-10-07
CIMR-VC4A0011 FS23639-15-07
CIMR-VC4A0018 FS23639-30-07
CIMR-VC4A0023 FS23639-30-07
CIMR-VC4A0031 FS23639-50-07
CIMR-VC4A0038 FS23639-50-07
Braking resistor Used to shorten the deceleration time by dissipating regenerative energy through a resistor (3% ED). ERF-150WJ series
24 V power supply
Provides power supply for the control circuit and option boards. Note: Parameter settings cannot be
changed when the drive is operating solely from this power supply.
PS-V10S
PS-V10M
USB copy unit
(RJ-45/USB compatible plug)
Adapter for connecting the drive to the USB port of a PC. (e.g. for Support Tool Drive Wizard Plus)
Can copy parameter settings to be later transferred to another drive.
JVOP-181
Support tools (DriveWizard Plus)
cable
Connects the drive to a PC for use with DriveWizard. WV103
LCD operator
For easier operation when using the optional LCD operator. Allows for remote operation. Includes a
Copy function for saving drive settings.
JVOP-180
LCD operator extension cable Cable for connecting the LCD operator.
WV001: 1 m
WV003: 3 m
Communication
interface
unit
MECHATROLINK-2
Allows control of the drive via a fieldbus network.
SI-T3/V
CC−link SI-C3/V
DeviceNet SI-N3/V
PROFIBUS−DP SI-P3/V
CANopen SI-S3/V
Momentary power loss recovery unit Ensures continued drive operation for a power loss of up to 2 s.
P0010 type (200 V class)
P0020 type (400 V class)
Attachment for external heatsink
Mechanical kit to install the drive with the heatsink out of the cabinet.
Note: current derating must be considered when this installation method is used.
(Please contact your YASKAWA
representative)
Screw-type terminal board Control terminal board with screw-type terminals. Available soon
Plus operator mounting kit
For the use with holes through the panel. 100-039-992
For the use with panel mounted threaded studs. 100-039-993
Note: contact the manufacturer in question for availability and specifications of non-YASKAWA products.